ERE 20 Reference Electrode

$ 0.00 AUD

The ERE 20 is a true, long life Reference Electrode, which can be cast into the cover concrete to monitor cathodic protection, electrochemical corrosion monitoring probes or the corrosion of steel inside concrete.

Request Call Back
Request Quote
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Based on proven battery technology, the ERE 20 is a true half-cell using a manganese dioxide electrode in steel housing with an alkaline, chloride-free gel. The steel housing is made of a corrosion resistant material. The pH of the gel corresponds to that of pore water in normal concrete, so errors due to diffusion of ions through the porous plug are eliminated. The potential of ERE 20 is virtually independent of changes in the chemical properties of the concrete. It can, therefore, be used in wet or dry concrete, whether exposed to chlorides or to carbonation.

Installation and Use

The ERE 20 can easily be attached to a logger in order to monitor data. Remote monitoring by modem is also possible.

The reinforcing steel to be protected shall be polarised a minimum of 100 mV at anodic locations. When using the polarisation decay method, the decay is determined by interrupting the protective current and monitoring the reinforcement’s potential measured relative to a stable reference electrode.

When the current is interrupted, an immediate voltage shift is the result of eliminating the IR-drop and is not to be included in the polarisation measurements. According to EN 12696 the Polarisation Decay should be met within 24 hours.

Advantages

  • Control of cathodic protection
  • For potential measurements in wet and dry concrete
  • Can be exposed to chloride or carbonation
  • Does not induce corrosion in steel
  • Does not change potential of steel
  • Easy to install in new or old structures

Example

The ERE 20 is used to check the correct operation of the cathodic protection in structures. The image below shows a typical curve found on checking a CP-system.

Polarisation Curve from a Cathodic Protection System
Model
ERE-20
Potential

Typical potential value measured in saturated Ca(OH)2 at 23°C is + 165 mV ver sus saturated calomel electrode (SCE) equal to + 410 mV in hydrogen scale.

The potential of a single electrode is not expected to be lower than + 150 mV vs SCE and higher than + 200 mV vs SCE.

Potential of ERE 20 Reference Electrode is checked prior to shipment and the potential versus saturated calomel electrode is supplied with each electrode.

Cable

5 meters single core, stranded copper conductor (flexible, 2.5 mm2) with XLPE insulation and PVC sheathing, color: blue.

Service life

The half-cell is in chemical equilibrium with the surrounding environment. Furthermore the manganese oxide, which exists as a natural mineral in the earth´s crust, will be stable in the long-time period.

The life time is governed by the amount of cell electrolyte, which has been set for more than 30 years of service.

ERE-20 Construction

A Box with coloured bands of MnO2, NaOh and Cement stacked vertically. A visual model showing the chemical makeup and layout inside an ERE-20 Electrode.